CO lines can be organized into trunk groups. The settings of each trunk group determine the settings of the CO lines within that group. A maximum of 64 (with the KX-TDA50/KX-TDA100/KX-TDA200) or 96 (with the KX-TDA600) trunk groups can be programmed. For more information on trunk groups, see "1.7.1 GROUP FEATURES" in the Feature Manual.
Main
Group Name
Specifies the name of the trunk group for programming reference.
Specifies the COS of the trunk group, applied when making a call from a CO line to another CO line with TIE Line Service. If you wish to prevent such calls from being made, ensure that the COS specified here has a TRS level of "7" assigned for all relevant time modes in 2.8.11 [2-7-1] Class of Service—COS Settings.
Specifies the CO line hunting sequence for the trunk group. The hunting sequence can be programmed to start from the lowest or highest numbered CO lines, or to rotate uniformly among all CO lines.
Trunk groups can be assigned a priority for Idle Line Access. When making a CO line call by Idle Line Access, the PBX will search trunk groups for an idle CO line according to the priority assigned here.
Trunk Group No. & Name
Specifies the trunk group assigned to the corresponding priority level. Select the blank option to not assign a trunk group to the priority.
Default
Priority 1–64 = Trunk Group No. 1–64
Value Range
For KX-TDA50/KX-TDA100/KX-TDA200: Trunk Group No. 1–64
Extensions can be assigned to a tenant according to their extension user groups. An extension user group can belong to only one tenant. However, one extension user group can belong to several call pickup groups and several paging groups. A maximum of 8 tenants can be programmed.
Extension Group Name
Specifies the name of the extension user group.
Default
For KX-TDA50/KX-TDA100/KX-TDA200: Extension User Group 1-32: Extension Group 01-32
For KX-TDA600: Extension User Group 1-96: Extension Group 01-96
Extensions can be assigned to a call pickup group according to their extension user groups. One extension user group can belong to up to 8 call pickup groups. A maximum of 64 (with the KX-TDA50/KX-TDA100/KX-TDA200) or 96 (with the KX-TDA600) call pickup groups can be programmed. To assign extension user groups to call pickup groups easily, click All Setting.
Extension Group Name
Indicates the name of the extension user group (reference only).
Default
For KX-TDA50/KX-TDA100/KX-TDA200: Extension User Group 1-32: Extension Group 01-32
For KX-TDA600: Extension User Group 1-96: Extension Group 01-96
Selects the call pickup groups that the extension user group belongs to. One extension user group can be assigned to a maximum of 8 call pickup groups on this screen. To assign an extension user group to more than 8 call pickup groups, click All Setting.
Extensions can be assigned to a call pickup group according to their extension user groups. One extension user group can belong to multiple call pickup groups.
Extensions can be assigned to a paging group according to their extension user groups. External pagers can also be assigned to a paging group. One extension user group or external pager can belong to multiple paging groups. A maximum of 32 (with the KX-TDA50/KX-TDA100/KX-TDA200) or 96 (with the KX-TDA600) paging groups can be programmed. To assign external pagers to paging groups, click External Pager. To assign extension user groups to paging groups easily, click All Setting.
Extension Group Name
Indicates the name of the extension user group (reference only).
Default
For KX-TDA50/KX-TDA100/KX-TDA200: Extension User Group 1-32: Extension Group 01-32
For KX-TDA600: Extension User Group 1-96: Extension Group 01-96
Selects the paging groups that the extension user group belongs to. One extension user group can be assigned to a maximum of 8 paging groups on this screen. To assign an extension user group to more than 8 paging groups, click All Setting.
Extensions can be assigned to a paging group according to their extension user groups. One extension user group or external pager can belong to multiple paging groups.
2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
Extensions can be assigned as members of an incoming call distribution group. Calls to an incoming call distribution group are distributed to its member extensions as programmed. A maximum of 128 incoming call distribution groups can be programmed. To view a list of all programmed extension numbers and types, click Extension List View (see 2.4.6 Tool—Extension List View). To assign extensions to ICD groups and change extension settings, click Member List. For more information on ICD Groups, see "1.9.1 ICD GROUP FEATURES" in the Feature Manual.
Main
Floating Extension Number
Specifies the floating extension number of the incoming call distribution group.
Note that groups that will have a mailbox using a VM in DPT integration must have extension numbers of 2–4 digits.
Default
Groups 001-064: 601–664 Groups 065-128: Not stored
Specifies the tenant to which the incoming call distribution group belongs, to determine the Time Table and the audio source for the group. (The tenant number corresponds to the Time Table number.)
Specifies the COS of the incoming call distribution group. Depending on the COS, calls from certain extensions are restricted as determined by the Internal Call Block feature. Also, when calls are forwarded or overflowed to a CO line, the TRS assigned for the COS of the incoming call distribution group applies.
Enables the PBX to play messages/BGM to the caller according to the Queuing Time Table, when the call arrives at an extension without being queued or after being queued.
Specifies the length of time that a call queues at an extension before it is redirected to the next member extension of the incoming call distribution group, in UCD or Priority Hunting distribution method.
Specifies the number of extensions that can accept calls simultaneously in the incoming call distribution group.
Default
Max.
Value Range
Max: Call arrives at an idle extension. 1–32 : Call will not arrive at an idle extension when the number of busy extensions exceeds the assigned number.
Specifies the extension number of the incoming call distribution group's supervisor. The supervisor can monitor and control the status of each member of the group using a 6-line display PT. The supervisor extension need not belong to the group.
2.9.10 [3-5-2] Incoming Call Distribution Group—Queuing Time Table
A Queuing Time Table can contain up to 16 sequences which control how calls waiting in a queue are handled. A maximum of 64 (with the KX-TDA50/KX-TDA100/KX-TDA200) or 128 (with the KX-TDA600) Queuing Time Tables can be programmed.
Queuing Sequence—Sequence 01–16
Specifies the command activated by the corresponding sequence.
Default
None
Value Range
None: Redirects the call to the next sequence Overflow: Redirects the call to the overflow destination when there is no answer Disconnect: Disconnects the line Sequence 01–16: Redirects the call to a different sequence Wait 5 × n (n=1–16) s: If preceded by an OGM, plays the Music on Hold for the specified period of time; if not preceded by an OGM, sends a ringback tone for the specified period of time.
KX-TDA50: OGM 01–32: Sends a certain OGM
KX-TDA100/KX-TDA200/KX-TDA600: OGM 01–64: Sends a certain OGM
2.9.11 [3-5-3] Incoming Call Distribution Group—Miscellaneous
Optional settings related to Incoming Call Distribution Groups can be programmed.
Options—Call Log to ICD Group for Answered Call
Selects whether answered calls to an ICD Group are also logged in the Incoming Call Log for the group, in addition to the log of the extension that answered the call.
Selects whether ICD Group buttons at extensions operate as normal or in Enhanced Phantom button mode. When set to Enhanced Phantom mode, creating an ICD Group button at an extension using PT personal programming automatically registers the extension as a member of the relevant ICD Group. The extension user can also specify the delayed ringing settings.
Extension: The timer is activated after all calls to or from the extension, including a retrieved call on hold. ICD Group Member: The timer is only activated after calls to the extension through an ICD Group.
2.9.12 [3-5-4] Incoming Call Distribution Group—Member
Each incoming call distribution group can have a maximum of 32 (with the KX-TDA50/KX-TDA100/KX-TDA200) or 128 (with the KX-TDA600) members (extensions) assigned to it, and each member can have its own delayed ringing and Wrap-up time settings. An extension can be a member of multiple incoming call distribution groups. An ICD Group can also contain cellular phones, and network ICD groups (ICD groups at other PBXs in a network) using virtual PS (see "1.19.2 Virtual PS" in the Feature Manual). The forward destination assigned to a virtual PS (e.g., a cellular phone) can act as a member of an ICD group. Select the desired ICD group (1–128) from the ICD Group No. list. To assign members to the group, enter directly or click Extension Number Setting (see 2.1.6 Extension Number Setting). To copy the members to another group, click Member List Copy, select the group, and click OK.
Extension Number
Specifies the extension number of each member. In addition to the extension numbers of PT, SLT, PS, and T1-OPX extensions, floating extension numbers of PS Ring groups can also be specified.
Specifies the delayed ringing setting of each member. (Applicable when the call distribution method of the incoming call distribution group is set to Ring.)
If an extension within an idle extension hunting group is called when it is busy or in DND mode, the call can be redirected to another extension in the same hunting group, according to a preprogrammed hunting type. If there is no idle extension in the group, the call can then be redirected to the overflow destination, which can be different depending on the time mode (day/lunch/break/night). A maximum of 64 (with the KX-TDA50/KX-TDA100/KX-TDA200) or 128 (with the KX-TDA600) hunting groups can be programmed, each containing up to 16 extensions. To assign members to the group, click Member List. To assign extensions as overflow destinations easily, click Destination Setting (see 2.1.6 Extension Number Setting).
Each hunting group can contain up to 16 extensions. Select the hunting group to program from the Hunting Group No. list. To assign members to the group, enter the extension numbers in Extension Numberor click Extension Number Setting (see 2.1.6 Extension Number Setting). To copy numbers to another group, click Member List Copy, select the group, and click OK.
Extension Number
Specifies the extension number of the hunting group member.
A Panasonic Voice Processing System (VPS) with DPT Integration can be connected to DPT ports of the PBX. The DPT ports that are connected to the VPS are called a VM (DPT) Group. With the KX-TDA50, a maximum of 1 VM (DPT) Group can be programmed; with the KX-TDA100/KX-TDA200, 2 VM (DPT) Groups can be programmed; and with the KX-TDA600, 8 VM (DPT) groups can be programmed.
Call Waiting on VM Group
Enables the queuing of calls when all extension ports of the VM (DPT) group are busy. (Call Waiting tone is not sent to any VM port.)
Enables the PBX to send the mailbox number of the called extension to the VPS when a call is redirected to the VM (DPT) group by Intercept Routing. When the VPS receives the mailbox number, the VPS answers the call with the appropriate mailbox.
Enables the PBX to send the mailbox number of the transfer destination extension to the VPS in these situations: (1) when a call is transferred to an extension by the Call Transfer without Announcement feature using the Automated Attendant (AA) service of the VPS, and the call is not answered within a programmed time period; (2) when the VPS is assigned as the Transfer Recall destination of a certain extension. When the VPS receives the mailbox number, the VPS answers the call with the appropriate mailbox.
A VM (DPT) group has a floating extension number, which can be assigned as the destination for redirected calls and incoming calls. To assign extension numbers to the group, click Member List. To view a list of all programmed extension numbers and types, click Extension List View.
Floating Extension No.
Specifies the floating extension number of the VM (DPT) group.
A Panasonic Voice Processing System (VPS) with DTMF Integration can be connected to SLT ports of the PBX. The SLT ports that are connected to the VPS are called a VM (DTMF) Group. A maximum of 2 (with the KX-TDA50/KX-TDA100/KX-TDA200) or 8 (with the KX-TDA600) VM (DTMF) Groups can be programmed. For more information on Voice Mail groups and DTMF integration, see "1.19.3 Voice Mail (VM) Group" and "1.19.5 Voice Mail DTMF Integration" in the Feature Manual.
VM DTMF Status Signal—Ringback Tone
Specifies the DTMF status signal the PBX sends to the VPS when the called extension is ringing.
Default
1
Value Range
Max. 4 digits (consisting of 0–9, *, #, and P [pause])
Specifies the DTMF status signal the PBX sends to the VPS when a certain feature (e.g., Message Waiting) has been successfully set or canceled on an extension.
Default
9
Value Range
Max. 4 digits (consisting of 0–9, *, #, and P [pause])
VM DTMF Status Signal—FWD to Extension Ringback Tone
Specifies the DTMF status signal the PBX sends to the VPS when the call has been forwarded to another extension and the PBX is calling the destination extension.
Default
8
Value Range
Max. 4 digits (consisting of 0–9, *, #, and P [pause])
Specifies the DTMF command the PBX sends to the VPS when a call is forwarded, intercepted, or transferred to the VPS, so that the caller can leave a message in a certain mailbox.
Default
H
Value Range
Max. 16 digits (consisting of 0–9, *, #, H [mailbox number], and P [pause])
Specifies the DTMF command the PBX sends to the VPS when an extension user answers a message waiting notification from the VPS, so that the extension user can retrieve a new message in a certain mailbox without having to dial the mailbox number manually.
Default
*H
Value Range
Max. 16 digits (consisting of 0–9, *, #, H [mailbox number], and P [pause])
Specifies which DTMF commands the VPS receives from the PBX when a call is forwarded to the VPS, so that the VPS can answer the call either with a mailbox or in the AA service mode. It is also possible to send no DTMF signal to the VPS.
Specifies which DTMF commands the VPS receives from the PBX when a call is intercepted to the VPS, so that the VPS can answer the call either with a mailbox or in the AA service mode. It is also possible to send no DTMF signal to the VPS.
Specifies whether the mailboxes use the same numbers as the extensions and incoming call distribution groups, or use different numbers as programmed for each extension or incoming call distribution group.
Specifies whether the PBX or VPS cancels the Message Waiting feature (e.g., turning off the MESSAGE button light) when an extension user answers the message waiting notification from the VPS.
A VM (DTMF) group has a floating extension number, and can be assigned as the destination for redirected calls and incoming calls. To assign members to the group, click Member List. To view a list of all programmed extension numbers and types, click Extension List View.
Floating Ext. No.
Specifies the floating extension number of the VM (DTMF) group.
2.9.20 [3-8-2] VM(DTMF) Group—Group Settings—Member List
Select the group to program from the VM(DTMF) Group Number list. To assign members to the group, enter directly or click Extension Number Setting (see 2.1.6 Extension Number Setting). To copy members to another group, click Member List Copy, select the group, and click OK.
Extension Number of the SLT Port Connected to VM
Specifies the extension number assigned to the SLT port that is connected to the VPS.
A PS ring group is a group of PS extensions that receives incoming calls. Each group has a floating extension number and name. One PS can belong to multiple PS ring groups. A maximum of 32 PS ring groups can be programmed, each containing up to 28 (with the KX-TDA50), 128 (with the KX-TDA100/KX-TDA200) or 512 (with the KX-TDA600) PS extensions. To add PSs to the PS Ring Group, click Member List.
Floating Extension Number
Specifies the floating extension number of the PS ring group.
Specifies the name of the PS ring group, which will be shown on the display of extensions that call the PS ring group when Incoming Trunk Call Information Display on this screen is set to Called Number.
Specifies the information of the incoming CO line call to be shown on the displays of the PSs that belong to the PS ring group. If the caller's name or called party's name is not recognized, the telephone number will be shown.
Each PS Ring Group can have up to 28 (with the KX-TDA50), 128 (with the KX-TDA100/KX-TDA200) or 512 (with the KX-TDA600) PS extensions assigned. Select the group to program from the PS Ring Group Number list. To assign members to the PS Ring Group, enter directly or click Extension Number Setting (see 2.1.6 Extension Number Setting). To copy members to another group, click Member List Copy, select the group, and click OK.
Extension Number
Specifies the extension number of the PS assigned to the PS Ring Group.