3.10 Connection of Doorphones, Door Openers, External Sensors, and External Relays
3.10.1 Connection of Doorphones, Door Openers, External Sensors, and External Relays
The PBX supports a maximum of 16 doorphones, 16 door openers, 16 external sensors, and 16 external relays.
Note
Doorphones, door openers, external sensors, and external relays are user-supplied.
Maximum Cabling Distance
Installing the Doorphone (KX-T30865)
1.
Loosen the screw to separate the doorphone into 2 halves.
2.
Pass the wires through the hole in the base cover, and attach the base cover to a wall using 2 screws.
Note
Two kinds of screws are included with a KX-T30865. Please choose the appropriate kind for your wall type.
: when a doorphone plate has been fixed to the wall
: when you wish to install the doorphone directly onto the wall
3.
Connect the wires to the screws located in the front cover.
4.
Re-attach the 2 halves and re-insert the screw.
Connection
Use 8-pin and 10-pin terminal blocks (included with the card) for connection.
1.
While pressing down on the hole at the top of the terminal block using a screwdriver, insert the wire into the side hole as shown below. Repeat this procedure for other doorphones, door openers, external sensors, and external relays. Refer to "3.7.2 DPH4 Card (KX-TDA0161)" and "3.7.3 EIO4 Card (KX-TDA0164)" for pin assignments.
2.
Attach the terminal blocks to the connectors of the DPH4/EIO4 card on the PBX.