| You cannot make/receive calls via an IP network. |
|
| • |
IP-EXT/IP-GW/DSP card malfunction |
|
| • |
Replace the corresponding card. |
|
| |
| • |
IPCMPR card malfunction |
|
| • |
Replace the IPCMPR card (be sure to turn off the PBX when replacing). |
|
| |
| • |
Not enough activation keys |
|
| • |
Purchase additional activation key codes. Please consult a certified dealer for details. |
|
| |
|
| • |
Make sure that an 8-pin twisted pair cable is used for connection. |
| • |
Make sure that none of the CAT 5 cables in use are over 100 m (328 ft) in length. |
| • |
Make sure that a straight cable is used for connection to a switching hub. |
|
| |
|
| • |
Make sure that all network devices in use are switched on. |
| • |
Make sure that there is no unwanted firewall in the IP network. |
|
| IP-PTs/SIP Extensions do not operate. |
|
| • |
IP-EXT/DSP card malfunction |
|
| • |
Replace the corresponding card. |
|
| |
| • |
IPCMPR card malfunction |
|
| • |
Replace the IPCMPR card (be sure to turn off the PBX when replacing). |
|
| |
| • |
Not enough activation keys |
|
| • |
Purchase additional activation key codes. Please consult a certified dealer for details. |
|
| |
| • |
IP-PT/SIP Extension not registered |
|
| • |
Register the corresponding IP-PT/SIP Extension. |
|
| |
| • |
IP-PT/SIP Extension malfunction |
|
| • |
Replace the IP-PT/SIP Extension. |
|
| |
|
| • |
Make sure that an 8-pin twisted pair cable is used for connection. |
| • |
Make sure that none of the CAT 5 cables in use are over 100 m (328 ft) in length. |
| • |
Make sure that a straight cable is used for connection to a switching hub. |
|
| |
|
| • |
Make sure that all network devices in use are switched on. |
| • |
Make sure that the IP-PT/SIP Extension is not blocked by the firewall or other network devices. |
|
| Extensions (except IP-PT/SIP Extension) do not operate. |
|
| • |
Extension card malfunction |
|
| • |
Replace the corresponding card. |
|
| |
| • |
Poor connection between the PBX and the extension |
|
| • |
Take the extension and plug it into the same extension port using a short telephone cord. If the extension works, then the connection between the PBX and the extension must be repaired. |
|
| |
| • |
A telephone with an A-A1 relay is connected. |
|
| • |
Make sure that a 2-wire cord is used. |
| • |
Make sure that the A-A1 relay switch of the telephone is in "OUT" or "OFF" position. |
|
| |
|
| • |
Take the extension and plug it into another extension port that is working. If the extension does not work, replace the extension. |
|
| |
|
| • |
Replace the PSU with the appropriate type. |
|
| The PBX does not operate properly. |
| |
| • |
Press the Reset Button (refer to "5.1.4 Using the Reset Button"). |
| • |
Turn off the power switch, and then turn it back on. |
| • |
Turn off the power switch, and then unplug the PBX. After 5 minutes, plug the PBX back in, and turn the power switch back on. |
|
| Noise on external paging. |
|
| • |
Induced noise on the wire between the PBX and the amplifier. |
|
| • |
Use a shielded cable as the connection wire between the PBX and amplifier. A short shielded cable is recommended. |
|
| Distorted external music. |
|
| • |
Excessive input level from external music source. |
|
| • |
Decrease the output level of the external music source by using the volume control on the music source. |
|
| Alternate Calling—Ring/Voice and Live Call Screening (LCS) do not function as set when using a Wireless Phone (KX-T7880/KX-T7885/KX-TD7894/KX-TD7895). |
|
| • |
Voice-calling mode and Hands-free mode with LCS are not available with Wireless Phones. |
|
| • |
Switch the calling mode to ring-calling. |
| • |
Set the LCS mode to "Private". |
|
| The ALARM indicator on the front of the shelf turns on red. |
|
| • |
A major system error occurs in the PBX. |
|
|
| The LINK indicator of the IP-EXT/IP-GW/IPCMPR does not turn on. |
|
| • |
IP-EXT/IP-GW card malfunction |
|
| • |
Replace the corresponding card. |
|
| • |
IPCMPR card malfunction |
|
| • |
Replace the IPCMPR card (be sure to turn off the PBX when replacing). |
|
|
|
| • |
Make sure that an 8-pin twisted pair cable is used for connection. |
| • |
Make sure that none of the CAT 5 cables in use are over 100 m (328 ft) in length. |
| • |
Make sure that a straight cable is used for connection to a switching hub. |
|
|
|
| • |
Make sure that all network devices in use are switched on. |
|